HBI CARGO Hold Wash Concentrate RX 25 Ltrs
Accumulation of dust from this cargo on deck or in proximity to cargo spaces shall be removed as quickly as possible. Consideration shall be given to carefully cleaning exposed radio communications equipment to which dust might adhere, such as radar, radio, aerials, vhf installations, AIS and GPS. Hosing with sea water should be avoided.
HBI CARGO Hold Wash Concentrate RX is a versatile all-purpose QUALITY marine cleaning solution. It can be used as a powerful stand-alone cleaner for HBI CARGO . it can be used as a powerful\ stand alone cleaner for HBI CARGO dust and deposition .
FEATURES & BENEFITS :-------------------
$ Heavy duty HBI CARGO remover action
$ Can be diluted to suit cleaning needs
$ Environmentally friendly
$ Safe to use in occupied / covered areas
$ Reduces turnaround times
$ Can be easily applied by ship's crew
$ using an RXSOL Application Set
Dosage
Useful Area
Industrial Usage
Other Valuable Hold Cleaners :::
Cement Remover RX Hold ::: Highly concentrated and powerful penetrating agents materials which is effectively react with cement to loosen the bonding strength . Best results can obtain on dry surface of cement. RXSOL'S R & D has developed this molecular cement dissolver. Part No.- RXSOL-22-2202-025, Part No.- RXSOL-22-2202-020, Part No.- RXSOL-22-2202-050
Part No.- RXSOL-22-2202-035, Part No.- RXSOL-22-2202-210
Bulletin Details
DISCRIPTION:
Accumulation of dust from this cargo on deck or in proximity to cargo spaces shall be removed as quickly as possible. Consideration shall be given to carefully cleaning exposed radio communications equipment to which dust might adhere, such as radar, radio, aerials, vhf installations, AIS and GPS. Hosing with sea water should be avoided.
HBI CARGO Hold Wash Concentrate RX is a versatile all-purpose QUALITY marine cleaning solution. It can be used as a powerful stand-alone cleaner for HBI CARGO . it can be used as a powerful\ stand alone cleaner for HBI CARGO dust and deposition .
MIXING INSTRUCTIONS
Fill a clean empty drum half way with FRESH water. Add required pails of Rxsol Hold Wash Concentrate (see dilution rates). Mix Well. Top up with water, stirring occasionally.
DILUTION RATES
Heavy-Duty Cleaner 1:1.5
3 Pails / Drum (75 ltrs:125 ltrs water)
General Cleaning 1:4
(50 ltrs:170 ltrs water) Hold Maintenance
APPLICATION INSTRUCTIONS:::HEAVY-DUTY CLEANER
Instructions for cleaning oily residues (HBI CARGO)
1. After discharge, remove as much remaining cargo as possible, as per normal procedures.
2. Do NOT wet surface before applying Hold Wash.
3. Mix 75 Ltrs of HBI CARGO Hold Wash Concentrate RX with approx 125 Ltrs of fresh water, as per Mixing Instructions.
4. Apply Rxsol Hold Wash liberally to affected areas with a low-pressure application system.
5. Allow to soak for about 5 minutes. DO NOT ALLOW TO DRY.
6. Use a fire hose or high-pressure Machine to clean the area. Use the highest pressure possible Water.
7. Some brushing and/or scrubbing may be required for stains.
GENERAL CLEANING
Instructions for general hold maintenance and light-duty cleaning (engine room, crew’s locker, kitchen, crane pedestals, etc.)
1. Mix 2 pails of HBI CARGO Hold Wash Concentrate RX with approx. 170 Ltrs of fresh water, as per Mixing Instructions. For small areas, simply dilute 1:4 in any type of container.
2. Apply HBI CARGO Hold Wash Concentrate RX liberally to affected areas.
3. Allow to soak for about 5 minutes. DO NOT ALLOW TO DRY.
4. Rinse clean with water.
HOW LONG TO SOAK?
5 minutes is only the suggested time. More time may be required for heavier residues. Determine the size of sections to clean and the soaking time by the current weather conditions. Clean small section in warm climates. In cooler temperatures, when drying time can be longer, clean larger sections. Do NOT allow HBI CARGO Hold Wash Concentrate RX to dry. If it does, then simply reapply.
PRECAUTIONS
Although HBI CARGO Hold Wash Concentrate RX is safe to use, it may cause skin or eye irritation with prolonged contact. As a precaution, wear protective gloves, goggles and a mask. Do not spray directly onto skin or eyes. Avoid prolonged breathing of mist.
Rxsol has the wide range of chemicals for cleaning chemicals for any type of vessel Including those carrying coal petcock & related to get the cargo hold clean for the next cargo choice of suitable cleaning chemical is essential & very important when applied the chemical resident type apply as important role as a surface active agent need time to penetrate & to take outside particular from the hold surface
Remarks
HBI at Elevated Temperatures
The Master of the ship must notify the port authorities if hydrogen gas is detected in the ship holds or if abnormal temperatures are measured in the HBI cargo holds. The Harbor Master and qualified personnel are responsible for executing the action plan when a ship or barge arrives with HBI at the following temperature levels:
A. Greater Than 65° Celsius but Less Than or Equal to 80° Celsius
Proceed with the following actions:
1 > Before unloading the vessel, measure the HBI temperature in each hold and record the measurements in the temperature log book.
2 > Unload the holds in the assigned zone and immediately transfer the HBI to the storage yard zone as described in PART II, Section 5.4 of this guide.
B. Temperature Greater Than 80° Celsius and Less Than or Equal to 150°
Celsius
Proceed with the following actions:
1 > Before unloading the vessel, measure the HBI temperature in each hold and record the measurements in the temperature log book. This should be done every two hours while the contingency is in effect.
2 > Unload the holds with HBI at temperature less than 65º Celsius first, then those containing HBI between 65º and 100º Celsius. Continue unloading HBI with temperatures between 100º and 150º Celsius in the
first transfer station, using the movement sense of the belt as a
reference.
3 > Transfer the HBI from the unloading zone clean and free of debris and flammable material, such as coal, coke and wood to the storage yard indicated by the client as follows:
Transfer the HBI during a maximum of three-minute intervals, and dose (i.e., mix the hotter with the cooler material to have an average temperature lower than the hottest one – no water to be used) the HBI that is at temperatures between 100° and 150° Celsius with cooler material for a maximum of two minutes. Stop the vibrating feeders for about five minutes, but keep the conveyor belts in motion. Repeat these steps until finished with HBI removal. While transferring the HBI, inspect the belt transfer system for any sign of overheating. In case of belt overheating, stop the HBI dosing and transfer but keep the transfer belts in motion until they cool. Take special care to avoid pouring water into hoppers and other equipment. Use a front-end loader to spread the HBI to a level of approximate 30 centimeter height to stop the reoxidation, Verify that the belts are cooled down and resume HBI transfer per
the previous instructions.
C . Greater than 150° Celsius
Proceed with the following actions:
1 > Before unloading the holds, measure the HBI temperature in each hold and record the measurements in the temperature log book. This should be done every two hours while the contingency is in effect.
2 > Position the HBI with temperatures greater than 150° Celsius at the end of the reception area and spray with pressurized water. In this case, there is no option but to momentarily cool down the HBI.
3 > When the temperature is reduced to between 80º and 150° Celsius proceed with the steps described in 6.3.2.2. Caution: Do not spray water on hot HBI that is steaming (i.e., emitting water vapor).
Procedure If Hydrogen Concentration Is Over 1% (25% LEL)
1 > Inform the shipper immediately and seek expert advice.
2 > Keep the natural surface ventilation open at all times
3 > Monitor LEL in the holds continuously until level drops to less than 25 %.
4 > Avoid any possible ignition source on the vicinity.
5 > Care shall be taken as to prevent any spark generation.
6 > Monitor the hydrogen concentration in the holds and keep the surface ventilation (either natural or mechanical) until values fall below 1%.
7 > When hydrogen levels are within safe values, proceed as normal.
8 > On the contrary, additional ventilation should be applied to the space if available and re-testing should be conducted after a suitable interval.
9 > Contact the P & I Club and Shipper and follow the instructions of the appointed expert or surveyor.
10 > At sea, do not open the troubled hold without explicit instructions from the shipper or appointed expert or surveyor.
11 > Ensure there are no possible sources of ignition near the cargo spaces, adjacent spaces or open decks.
Supply Locations
HBI Cargo Residue Cleaner Chemical is helpful to clean HBI cargo stain by chemicals cleaning and reactive principle. We are HBI CARGO Residue cleaner supplier in Paradip, Haldia, Hazira, Mundra, Kandla, Ennore, Kochin, Visakhapatnam, Sohar, Muscat, Fujairah, Dubai, Sharjah, Mumbai, Manglore and Goa, Ruwi Barka, Abudhabi, Ajman, Sudan, Yemen, Canada